Simatic net pc software update
Simatic net pc software update









simatic net pc software update
  1. Simatic net pc software update how to#
  2. Simatic net pc software update install#

The New subnet MPI dialog MPI dialog box appears: Click New (following figure):įigure 14: New interface setting (caption) Note We will change the Bus address to correspond to the actual Bus address of the CP5611 card i n a subsequent step. Click Properties (see following figure):įigure 13: Properties - CP 5611 dialog box The MPI interface dialog interface dialog box appears (following figure): 9. The Properties - CP 5611 dialog box reappears. Setting Up an MPI Connection with Siemens SIMATIC NET 6.0 Software Using a C. In the Interface Type: area (shown above), open the Type: drop-down list and select MPI MPI. Double click the CP5611 CP5611 module module that you just added to Index 2. The following figure shows the CP 5611 in index 2:įigure 10: Item 2 - CP5611 4. PCStation (see PCStation (see following figure): Select the CP 5611 module (under the CP Profibus folder), and drag it to the second line of the (0) PC box. This creates Index 2 for the CP5611 component in the 2. PC, and drop in the first line in order to configure the Application component as Index 1 (see following figure): Drag it over to the the top left box labeled (0) PC, Application. Add the Application component of the PCStation Application. In the previous figure, it appears under User 1. PCStation by by selecting it in the right hand pane of the PC Config window.

simatic net pc software update

Setting up the PCStation in the SIMATIC Manager PC Config Screen The following window should now be visible: Double-click the Configuration Configuration Icon Icon in the right pane of the above figure to open up the SIMATIC Manager PC Config screen. Note The Note The PCStation name MUST must match up with the name in the Station Configuration Editor (see Figure 51 51). Station, right-click, and select Rename Rename. Enter PCStation PCStation (following (following figures) as the new name: 4.Highlight SIMATIC PC Station, Insert/Station/SIMATIC tation/SIMATIC PC Station Station (see (see following figure) from the main menu: 3. In the above example, MPI2 MPI2 was was used. Enter a project name name in the Name: box and click OK OK. Note On your desktop, you should see an ICON like the following: Note to start a new project. Click on File/New File/New from from the SIMATIC Manager main menu. Starting a new Project with SIMATIC Manager 1. Make sure that the S7 Plc is connected via the MPI cable to the pc and is in Run mode.

Simatic net pc software update install#

Install the Wonderware Siemens S7 I/O Server version 7,5,0,11. Install the MPI cable (Connect it from the CP5611 adapter card to the MPI port on the CPU of the S7.) Siemens part number (6ES7901-0BF00-0AA0). Install the Siemens SIMATIC NET 6.0 Software + SP2 or higher. OF PC/PG WITH PCI BUS TO PROFIBUS OR MPI INCL. The following are part numbers for the CP5611 separately: 6GK1561-1AA00 - SIMATIC NET, PB, CP 5611 PCI CARD (32 BIT) FOR CONNECTION OF A PG OR PC WITH PCI BUS TO PROFIBUS OR MPI 6GK1561-1AA00 6GK1561-1AM00 6GK1561-1AM00 - SIMATIC NET, PB, CP 5611-MPI CONS. Install the Siemens CP5611 adapter card part number (6GK15611AM00 - CP5611 + MPI-cable ) on your pc.

Simatic net pc software update how to#

This Tech Note outlines outlines how to set up an MPI connection with Siemens SIMATIC NET 6.0 software using a CP5611 Profibus Card and an S7-400 PLC (CPU 413-1).īefore You Get started, Please Do the Following: 1. See the Terms of Use for Use for more information. Setting Up an MPI Connection with Siemens SIMATIC NET 6.0 Software Using a CP5611 Profibus Card and an S7-400 PLC (CPU 413-1) Tech Note 303Īll Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind.

simatic net pc software update









Simatic net pc software update